Our 6 store locations may sell for less if you are able to pick up your battery.
For Dealer and volume purchase enquirers CLICK HERE.
All requests for quotation will be processed within 24hrs eastern standard time, please indicate part, quantity required and your shipping destination commercial quotations.
* Includes shipping to any Canadian provinces except Quebec and the Territories, please contact online for shipping information to those locations.
A solar charger gathers energy from your solar panels, and stores it in your batteries. Using the latest, fastest technology, SmartSolar maximises this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. SmartSolar maintains battery health, extending its life.
The SmartSolar charge controller will even recharge a severely depleted battery. It can operate with a battery voltage as low as 0 Volts, provided the cells are not permanently sulphated or otherwise damaged.
Models:
12/24/36/48 Volt
Introducing the SmartSolar MPPT 250/100
Bluetooth Smart built-in
The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers.
Ultra-fast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast
MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers
and by up to 10% compared to slower MPPT controllers.
Advanced Maximum
Power Point Detection in case of partial shading conditions
If partial shading occurs, two or more maximum power points (MPP) may be present on the
power-voltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
The innovative SmartSolar algorithm will always maximize energy harvest by locking to the
optimum MPP.
Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 98%.
Flexible charge algorithm
Fully programmable charge algorithm (see the software page on our website), and eight preprogrammed algorithms, selectable with a rotary switch (see manual for details).
Extensive electronic protection
Over-temperature protection and power derating when temperature is high.
PV short circuit and PV reverse polarity protection.
PV reverse current protection.
Internal temperature sensor
Compensates absorption and float charge voltage for temperature.
Optional external battery voltage, temperature and current sensing via Bluetooth
A Smart Battery Sense, a BMV-712 Smart Battery Monitor or a SmartShunt can be used to
communicate battery voltage and temperature (and current, in case of a BMV 712 or a
SmartShunt) to one or more SmartSolar Charge Controllers.
Synchronized parallel charging with Bluetooth
Up to 10 units can be synchronized with Bluetooth.
Fully discharged battery recovery function
Will initiate charging even if the battery has been discharged to zero volts.
Will reconnect to a fully discharged Li-ion battery with integrated disconnect function.
VE.Direct
For a wired data connection to a Color Control GX, other GX products, PC or other devices
Remote on-off
To connect for example to a VE.BUS BMS.
Programmable relay
Can be programmed to trip on an alarm, or other events.
Optional: SmartSolar pluggable LCD display
Simply remove the rubber seal that protects
the plug on the front of the controller,
and plug-in the display.
SmartSolar Charge Controller |
150/45 |
150/60 |
150/70 |
Battery voltage |
12 / 24 / 48V Auto Select (software tool needed to select 36V) |
Rated charge current |
45A |
60A |
70A |
Nominal PV power, 12V 1a,b) |
650W |
860W |
1000W |
Nominal PV power, 24V 1a,b) |
1300W |
1720W |
2000W |
Nominal PV power, 36V 1a,b) |
1950W |
2580W |
3000W |
Nominal PV power, 48V 1a,b) |
2600W |
3440W |
4000W |
Max. PV short circuit current 2) |
50A (max 30A per MC4 conn.) |
Maximum PV open circuit voltage |
150V absolute maximum coldest conditions
145V start-up and operating maximum |
Maximum efficiency |
98% |
Self-consumption |
Less than 35mA @ 12V / 20mA @ 48V |
Charge voltage 'absorption' |
Default setting: 14,4 / 28,8 / 43,2 / 57,6V
(adjustable with: rotary switch, display, VE.Direct or Bluetooth) |
Charge voltage 'float' |
Default setting: 13,8 / 27,6 / 41,4 / 55,2V
(adjustable: rotary switch, display, VE.Direct or Bluetooth) |
Charge voltage 'equalization' |
Default setting: 16,2V / 32,4V / 48,6V / 64,8V (adjustable) |
Charge algorithm |
multi-stage adaptive (eight pre-programmed algorithms) or user defined algorithm |
Temperature compensation |
-16 mV / -32 mV / -64 mV / °C |
Protection |
PV reverse polarity / Output short circuit / Over temperature |
Operating temperature |
-30 to +60°C (full rated output up to 40°C) |
Humidity |
95%, non-condensing |
Maximum altitude |
5000m (full rated output up to 2000m) |
Environmental condition |
Indoor, unconditioned |
Pollution degree |
PD3 |
Data communication port |
VE.Direct or Bluetooth |
Remote on/off |
Yes (2 pole connector) |
Programmable relay |
DPST AC rating: 240VAC / 4A DC rating: 4A up to 35VDC, 1A up to 60VDC |
Parallel operation |
Yes: up to 10 units can be synchronized with Bluetooth |
ENCLOSURE |
Colour |
Blue (RAL 5012) |
PV terminals 3) |
35 mm2 / AWG2 (Tr models) Two pairs of MC4 connectors (MC4 models) |
Battery terminals |
35mm2 / AWG2 |
Protection category |
IP43 (electronic components), IP22 (connection area) |
Weight |
3 kg |
Dimensions (h x w x d) |
Tr models: 185 x 250 x 95 mm MC4 models: 215 x 250 x 95 mm |
STANDARDS |
Safety |
EN/IEC 62109-1, UL 1741, CSA C22.2 |
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V.
2) A PV array with a higher short circuit current may damage the controller.
3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels
Maximum current per MC4 connector: 30A (the MC4 connectors are parallel connected to one MPPT tracker) |
SmartSolar Charge Controller |
250/60 |
250/70 |
Battery voltage |
12 / 24 / 48V Auto Select (software tool needed to select 36V) |
Rated charge current |
60A |
70A |
Nominal PV power, 12V 1a,b) |
860W |
1000W |
Nominal PV power, 24V 1a,b) |
1720W |
2000W |
Nominal PV power, 36V 1a,b) |
2580W |
3000W |
Nominal PV power, 48V 1a,b) |
3440W |
4000W |
Max. PV short circuit current 2) |
35A (max 30A per MC4 conn.) |
Maximum PV open circuit voltage |
250V absolute maximum coldest conditions
245V start-up and operating maximum |
Maximum efficiency |
99% |
Self-consumption |
Less than 35mA @ 12V / 20mA @ 48V |
Charge voltage 'absorption' |
Default setting: 14,4 / 28,8 / 43,2 / 57,6V
(adjustable with: rotary switch, display, VE.Direct or Bluetooth) |
Charge voltage 'float' |
Default setting: 13,8 / 27,6 / 41,4 / 55,2V
(adjustable: rotary switch, display, VE.Direct or Bluetooth) |
Charge voltage 'equalization' |
Default setting: 16,2V / 32,4V / 48,6V / 64,8V (adjustable) |
Charge algorithm |
multi-stage adaptive (eight pre-programmed algorithms)
or user defined algorithm |
Temperature compensation |
-16 mV / -32 mV / -64 mV / °C |
Protection |
PV reverse polarity / Output short circuit / Over temperature |
Operating temperature |
-30 to +60°C (full rated output up to 40°C) |
Humidity |
95%, non-condensing |
Maximum altitude |
5000m (full rated output up to 2000m) |
Environmental condition |
Indoor, unconditioned |
Pollution degree |
PD3 |
Data communication port |
VE.Direct or Bluetooth |
Remote on/off |
Yes (2 pole connector) |
Programmable relay |
DPST AC rating: 240VAC / 4A DC rating: 4A up to 35VDC, 1A up to 60VDC |
Parallel operation |
Yes: up to 10 units can be synchronized with Bluetooth |
ENCLOSURE |
Colour |
Blue (RAL 5012) |
PV terminals 3) |
35 mm2 / AWG2 (Tr models) Two pairs of MC4 connectors (MC4 models) |
Battery terminals |
35mm2 / AWG2 |
Protection category |
IP43 (electronic components), IP22 (connection area) |
Weight |
3 kg |
Dimensions (h x w x d) |
Tr models: 185 x 250 x 95 mm
MC4 models: 215 x 250 x 95 mm |
STANDARDS |
Safety |
EN/IEC 62109-1, UL 1741, CSA C22.2 |
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V.
2) A PV array with a higher short circuit current may damage the controller.
3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels
Maximum current per MC4 connector: 30A (the MC4 connectors are parallel connected to one MPPT tracker) |
|
|
|
|
|
|
|