Our 6 store locations may sell for less if you are able to pick up your battery.
For Dealer and volume purchase enquirers CLICK HERE.
All requests for quotation will be processed within 24hrs eastern standard time, please indicate part, quantity required and your shipping destination commercial quotations.
* Includes shipping to any Canadian provinces except Quebec and the Territories, please contact online for shipping information to those locations.
With integrated cell balancing
Can be parallel and series connected
Bluetooth app available to monitor cell voltage and temperature Requires one of these BMS-es:
VE.Bus BMS - recommended for systems with our inverter/chargers.
smallBMS - recommended for use in small systems.
Battery Management System BMS 12/200 - recommended for use in Automotive and Marine systems having DC-loads and Alternators.
Smart BMS 12/200 - recommended for use in Automotive and Marine systems having DC-loads and Alternators.
Smart BMS CL 12/100 - recommended for use in Automotive and Marine systems having DC-loads and Alternators.
Lynx Smart BMS - recommended for use in large systems.
Rugged
A lead-acid battery will fail prematurely due to sulfation:
- If it operates in deficit mode during long periods of time (i.e. if the battery is rarely, or never at all,
fully charged).
- If it is left partially charged or worse, fully discharged (yacht or mobile home during wintertime).
A LFP battery does not need to be fully charged. Service life even slightly improves in case of partial charge
instead of a full charge. This is a major advantage of LFP compared to lead-acid.
Other advantages are the wide operating temperature range, excellent cycling performance, low internal
resistance and high efficiency (see below).
LFP is therefore the chemistry of choice for demanding applications.
Efficient
In several applications (especially off-grid solar and/or wind), energy efficiency can be of crucial importance.
The round-trip energy efficiency (discharge from 100% to 0% and back to 100% charged) of the average leadacid battery is 80%.
The round-trip energy efficiency of a LFP battery is 92%.
The charge process of lead-acid batteries becomes particularly inefficient when the 80% state of charge has
been reached, resulting in efficiencies of 50% or even less in solar systems where several days of reserve energy
is required (battery operating in 70% to 100% charged state).
In contrast, a LFP battery will still achieve 90% efficiency under shallow discharge conditions.
Size and weight
Saves up to 70% in space
Saves up to 70% in weight
Expensive?
LFP batteries are expensive when compared to lead-acid. But in demanding applications, the high initial cost
will be more than compensated by longer service life, superior reliability and excellent efficiency.
Bluetooth
With Bluetooth cell voltages, temperature and alarm status can be monitored.
Very useful to localize a (potential) problem, such as cell imbalance.
Battery specification
|
VOLTAGE AND CAPACITY
|
LFPSmart 12,8/50
|
LFPSmart 12,8/60
|
LFPSmart 12,8/100
|
LFPSmart 12,8/160
|
LFPSmart 12,8/200
|
LFPSmart 12,8/300
|
LFP- Smart 12,8/330
|
LFP- Smart 25,6/100
|
LFPSmart 25,6/200
|
LFPSmart 25,6/200-a
|
Nominal voltage
|
12,8V
|
12,8V
|
12,8V
|
12,8V
|
12,8V
|
12,8V
|
12,8V
|
25,6V
|
25,6V
|
25,6V
|
Nominal capacity @ 25°C*
|
50Ah
|
60Ah
|
100Ah
|
160Ah
|
200Ah
|
300Ah
|
330Ah
|
100Ah
|
200Ah
|
200Ah
|
Nominal capacity @ 0°C*
|
40Ah
|
48Ah
|
80Ah
|
130Ah
|
160Ah
|
240Ah
|
260Ah
|
80Ah
|
160Ah
|
160Ah
|
Nominal capacity @ -20°C*
|
25Ah
|
30Ah
|
50Ah
|
80Ah
|
100Ah
|
150Ah
|
160Ah
|
50Ah
|
100Ah
|
100Ah
|
Nominal energy @ 25°C*
|
640Wh
|
768Wh
|
1280Wh
|
2048Wh
|
2560Wh
|
3840Wh
|
4220Wh
|
2560Wh
|
5120Wh
|
5120Wh
|
*Discharge current ?1C
|
CYCLE LIFE (capacity ≥ 80% of nominal)
|
80% DoD
|
2500 cycles
|
70% DoD
|
3000 cycles
|
50% DoD
|
5000 cycles
|
DISCHARGE
|
Maximum continuous discharge current
|
100A
|
120A
|
200A
|
320A
|
400A
|
600A
|
400A
|
200A
|
400A
|
400A
|
Recommended continuous discharge current
|
≤50A
|
≤60A
|
≤100A
|
≤160A
|
≤200A
|
≤300A
|
≤300A
|
≤100A
|
≤200A
|
≤200A
|
End of discharge voltage
|
11,2V
|
11,2V
|
11,2V
|
11,2V
|
11,2V
|
11,2V
|
11,2V
|
22,4V
|
22,4V
|
22,4V
|
Internal resistance
|
2mΩ
|
2mΩ
|
0,8mΩ
|
0,9mΩ
|
0,8mΩ
|
0,8mΩ
|
0,8mΩ
|
1,6mΩ
|
1,5mΩ
|
1,5mΩ
|
OPERATING CONDITIONS
|
Operating temperature
|
Discharge: -20°C to +50°C Charge: +5°C to +50°C
|
Storage temperature
|
-45°C to +70°C
|
Humidity (non-condensing)
|
Max. 95%
|
Protection class
|
IP 22
|
CHARGE
|
Charge voltage
|
Between 14V/28V and 14,4V/28,8V (14,2V/28,4V recommended)
|
Float voltage
|
13,5V/27V
|
Maximum charge current
|
100A
|
120A
|
200A
|
320A
|
400A
|
600A
|
400A
|
200A
|
400A
|
400A
|
Recommended charge current
|
≤30A
|
≤30A
|
≤50A
|
≤80A
|
≤100A
|
≤150A
|
≤150A
|
≤50A
|
≤100A
|
≤100A
|
OTHER
|
Max storage time @ 25°C*
|
1 year
|
BMS connection
|
Male + female cable with M8 circular connector, length 50cm
|
Power connection (threaded inserts)
|
M8
|
M8
|
M8
|
M8
|
M8
|
M10
|
M10
|
M8
|
M8
|
M8
|
Dimensions (hxwxd) mm
|
199 x 188 x 147
|
239 x 286 x132
|
197 x 321 x 152
|
237 x 321 x 152
|
237 x 321 x 152
|
347 x 425 x 274
|
265 x 359 x 206
|
197 x 650 x 163
|
317 x 631 x 208
|
237 x 650 x 163
|
Weight
|
7kg
|
12kg
|
14kg
|
18kg
|
20kg
|
51kg
|
30kg
|
28kg
|
56kg
|
39kg
|
*When fully charged
|
|
|
|
|
|
|
|