Our 6 store locations may sell for less if you are able to pick up your battery.
For Dealer and volume purchase enquirers CLICK HERE.
All requests for quotation will be processed within 24hrs eastern standard time, please indicate part, quantity required and your shipping destination commercial quotations.
* Includes shipping to any Canadian provinces except Quebec and the Territories, please contact online for shipping information to those locations.
VRLA AGM: design life 7-10 years
VRLA GEL: design life 12 years
VRLA GEL 2 Volt cells: design life 20 years
The AGM range has very low internal resistance making them particularly suitable for high current discharge applications such as for inverters, thrusters and winches.
The GEL model range offers best deep cycle durability and overall longer life. The use of high purity materials and lead calcium grids ensure that for both AGM and GEL products have particularly low self-discharge so that they will not go flat during long periods without charge. Both ranges are supplied with M8 drilled, flat copper terminals ensuring best possible connection contact and eliminating the need for battery terminals. The batteries are compliant with both CE and UL specifications in ABS fireproof containers and come with Victron's 2 year world-wide warranty.
Gel and AGM Batteries
1. VRLA technology
2. Sealed (VRLA) AGM Batteries
3. Sealed (VRLA) Gel Batteries
4. Low Self-Discharge
5. Exceptional Deep Discharge Recovery
6. Battery Discharging Characteristics
7. Effect of temperature on service life
Average Temperature
|
AGM ‘Deep Cycle’ years
|
Gel ‘Deep Cycle’ years
|
Gel ‘Long Life’ years
|
20°C / 68°F
|
7 - 10
|
12
|
20
|
30°C / 86°F
|
4
|
6
|
10
|
40°C / 104°F
|
2
|
3
|
5
|
8. Effect of temperature on capacity
9. Cycle life of Victron batteries
10. Battery charging in case of cycle use: the 3-step charge curve
11. Battery charging: longer battery life with Victron 4-step adaptive charging
The Victron four-step adaptive charge curve solves the 3 main problems of the 3-step curve:
- Battery Safe Mode
- Variable absorption time
- Storage mode
12. Battery charging in case of standby use: constant voltage float charging
13. Optimum charge voltage of Victron VRLA batteries
14. Effect of temperature on charging voltage
15. Charge current
|
Float Service
(V)
|
Cycle service
Normal (V)
|
Cycle service
Fastest recharge (V)
|
Victron AGM 'Deep Cycle'
|
Absorption
|
|
14,2 - 14,6
|
14,6 - 14,9
|
Float
|
13,5 - 13,8
|
13,5 - 13,8
|
13,5 - 13,8
|
Storage
|
13,2 - 13,5
|
13,2 - 13,5
|
13,2 - 13,5
|
Victron Gel 'Deep Cycle'
|
Absorption
|
|
14,1 - 14,4
|
|
Float
|
13,5 - 13,8
|
13,5 - 13,8
|
|
Storage
|
13,2 - 13,5
|
13,2 - 13,5
|
|
Victron Gel 'Long Life'
|
Absorption
|
|
14,0 - 14,2
|
|
Float
|
13,5 - 13,8
|
13,5 - 13,8
|
|
Storage
|
13,2 - 13,5
|
13,2 - 13,5
|
|
12 Volt Deep Cycle AGM
|
General Specification
|
Article number
|
Ah
|
V
|
l x w x h mm
|
Weight kg
|
CCA @0°F>
|
RES CAP @80°F
|
Technology: flat plate AGM Terminals: copper
|
BAT406225084
|
240
|
6
|
320 x 176 x 247
|
31
|
700
|
270
|
Rated capacity: 20 hr. discharge at 25°C Float design life: 7-10 years at 20°C Cycle design life: 400 cycles at 80% discharge 600 cycles at 50% discharge 1500 cycles at 30% discharge
|
BAT212070084
|
8
|
12
|
151 x 65 x 101
|
2,5
|
|
|
BAT212120086
|
14
|
12
|
151 x 98 x 101
|
4,4
|
|
|
BAT212200084
|
22
|
12
|
181 x 77 x 167
|
5,8
|
|
|
BAT412350084
|
38
|
12
|
197 x 165 x 170
|
12,5
|
|
|
BAT412550084
|
60
|
12
|
229 x 138 x 227
|
20
|
280
|
80
|
BAT412600084
|
66
|
12
|
258 x 166 x 235
|
24
|
300
|
90
|
BAT412800084
|
90
|
12
|
350 x 167 x 183
|
27
|
400
|
130
|
BAT412101084
|
110
|
12
|
330 x 171 x 220
|
32
|
500
|
170
|
BAT412121084
|
130
|
12
|
410 x 176 x 227
|
38
|
550
|
200
|
BAT412151084
|
165
|
12
|
485 x 172 x 240
|
47
|
600
|
220
|
BAT412201084
|
220
|
12
|
522 x 238 x 240
|
65
|
650
|
250
|
BAT412124081
|
240
|
12
|
522 x 240 x 224
|
67
|
650
|
250
|
12 Volt Deep Cycle GEL
|
General Specification
|
Article number
|
Ah
|
V
|
l x w x h mm
|
Weight kg
|
CCA @0°F
|
RES CAP @80°F
|
Technology: flat plate AGM Terminals: copper
|
BAT412550104
|
60
|
12
|
229 x 138 x 227
|
20
|
250
|
70
|
Rated capacity: 20 hr. discharge at 25°C Float design life: 12 years at 20°C Cycle design life: 500 cycles at 80% discharge 750 cycles at 50% discharge 1800 cycles at 30% discharge
|
BAT412600100
|
66
|
12
|
258 x 166 x 235
|
24
|
270
|
80
|
BAT212120086
|
90
|
12
|
350 x 167 x 183
|
26
|
360
|
120
|
BAT412101104
|
110
|
12
|
330 x 171 x 220
|
33
|
450
|
150
|
BAT412121104
|
130
|
12
|
410 x 176 x 227
|
38
|
500
|
180
|
BAT412151104
|
165
|
12
|
229 x 138 x 227
|
48
|
550
|
200
|
BAT412201104
|
220
|
12
|
522 x 238 x 240
|
66
|
600
|
220
|
BAT412126101
|
265
|
12
|
520 x 268 x 223
|
27
|
400
|
130
|
BAT412101084
|
110
|
12
|
330 x 171 x 220
|
75
|
650
|
250
|
|
|
|
|
|
|
|