Similar to the MultiPlus, the Quattro is also a combined inverter and charger. Additionally it can accept two AC inputs and automatically connect to the active source. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology plus multiple system integration features such as three or split phase operation and parallel operation.
Models:
3000VA, 5000VA, 8000VA, 10000VA, 15000VA
0:06 / 5:37 VE Configure 3 basic | Victron Energy
Multifunctional
Similar to the MultiPlus, the Quattro is also a combined inverter and charger. Additionally it can accept two AC inputs and automatically connect to the active source. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology plus multiple system integration features such as three or split phase operation and parallel operation.
Two AC Inputs & two AC Outputs
The Quattro can be connected to two independent AC sources, for example shore-side power and a generator, or two generators. The Quattro will automatically connect to the active source. The main output has no-break functionality. In the event of a grid failure, or shore or generator power being disconnected, the Quattro takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge the battery, such as air-conditioning or a water heater can be connected to this output.
Unique PowerAssist feature
The Quattro will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shore side supply with power taken from the battery.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattros can operate in parallel to achieve higher power output. Three phase or split phase operation is also possible. Please check our datasheets to see which models have paralleling, three phase and split phase capabilities.
Remote Monitoring and Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Quattro and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Quattro to auto starting a backupgenerator and more...
Quattro |
48/3000/35-50/50 120V |
12/5000/220-100/100 120V 24/5000/120-100/100 120V 48/5000/70-100/100 120V |
48/10000/140-100/100 120V |
PowerControl / PowerAssist |
Yes |
Integrated Transfer switch |
Yes |
AC inputs (2x) |
Input voltage range: 90-140 VAC Input frequency: 45 – 65 Hz Power factor: 1 |
Maximum feed through current |
2x 50 A |
2x 100 A |
2x 100 A |
INVERTER |
Input voltage range |
9,5 – 17 V 19 – 33V 38 – 66 V |
Output (1) |
Output voltage: 120 VAC ± 2% Frequency: 60 Hz ± 0,1% |
Cont. output power at 25°C (3) |
3000 VA |
5000 VA |
10000 VA |
Cont. output power at 25°C |
2400 W |
4000 W |
8000 W |
Cont. output power at 40°C |
2200 W |
3700 W |
6500 W |
Cont. output power at 65°C |
1700 W |
3000 W |
4500 W |
Peak power |
6000 W |
10000 W |
20000 W |
Maximum efficiency |
94 % |
94 / 94 / 95 % |
96 % |
Zero load power |
25 W |
30 / 30 / 35 W |
60 W |
Zero load power in AES mode |
20 W |
20 / 25 / 30 W |
40 W |
Zero load power in Search mode |
12 W |
10 / 10 / 15 W |
15 W |
CHARGER |
Charge voltage 'absorption' (V DC) |
57,6 V |
14,4 / 28,8 / 57,6 V |
57,6 V |
Charge voltage 'float' (V DC) |
55,2 V |
13,8 / 27,6 / 55,2 V |
55,2 V |
Storage mode (V DC) |
52,8 V |
13,2 / 26,4 / 52,8 V |
52,8 V |
Charge current house battery (A) (4) |
35 A |
200 / 120 / 70 A |
140 A |
Charge current starter battery (A) |
4 A (12V and 24V models only) |
Battery temperature sensor |
Yes |
GENERAL |
Auxiliary output (5) |
32 A |
50 A |
50 A |
Programmable relay (6) |
3x |
Protection (2) |
a-g |
VE.Bus communication port |
For parallel, split phase and three phase operation, remote monitoring and system integration |
General purpose com. port |
2x |
Remote on-off |
Yes |
Common Characteristics |
Operating temp.: -40 to +65?C Humidity (non-condensing): max. 95% |
ENCLOSURE |
Common Characteristics |
Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21 |
Battery-connection |
Four M8 bolts (2 plus and 2 minus connections) |
120 V AC-connection |
Screw terminals 13 mm2 (6 AWG) |
Bolts M6 |
Bolts M6 |
Weight (kg) |
42 lb 19 kg |
75 / 66 / 66 lb 34 / 30 / 30 kg |
128 lb 58 kg |
Dimensions (hxwxd) |
14.3 x 10.2 x 8.6 inch 362 x 258 x 218 mm |
18,5 x 14,0 x 11,2 inch 470 x 350 x 280 mm 17,5 x 13,0 x 9,6 inch 444 x 328 x 240 mm 17,5 x 13,0 x 9,6 inch 444 x 328 x 240 mm |
22.6 x 19,2 x 13,6 inch 572 x 488 x 344 mm |
STANDARDS |
Safety |
EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1 |
Emission, Immunity |
EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |
Road vehicles |
12V and 24V models: ECE R10-5 |
1) Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 120 VAC on inverter output
g) input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25?C ambient
5) Switches off when no external AC source available
6) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function AC rating: 230 V / 4 A DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC |
|
|
|
|
|
|
|