| Lynx Smart BMS |
|
| POWER |
| Supply voltage range |
9 - 58 Vdc |
| Supported system voltages |
12, 24 or 48V |
| Reverse polarity protection |
No |
| Main safety contactor continuous current rating |
500Adc continuous |
| Main safety contactor peak current rating |
600A for 5 minutes |
| Power consumption hibernate or standby mode |
Approximately 10.4mW (0.8mA at 13V) |
| Power consumption in active mode |
Approximately 2.6W (200mA at 13V) depending on the state of the relays |
| Minimum load resistance for pre-charging |
10Ω and above for 12V systems 20Ω and above for 24V and 48V systems |
| AUX output maximum current rating |
1.1A continuous, protected by resettable fuse |
| Allow-to-charge port Maximum current rating |
0.5A at 60Vdc, protected by resettable fuse |
| Allow-to-discharge port Maximum current rating |
0.5A at 60Vdc, protected by resettable fuse |
| Alarm relay (SPDT) Maximum current rating |
2A at 60Vdc |
| CONNECTIONS |
| Busbar |
M8 |
| VE.Can |
RJ45 and RJ45 terminator |
| I/O |
Screw terminals |
| Battery BMS cables |
Male and female circular 3-pole connector with M8 screw ring |
| Lynx distributor (up to 4 modules) |
RJ10 (cable ships with each Lynx Distributor) |
| PHYSICAL |
| Enclosure material |
ABS |
| Enclosure dimensions (h x w x d) |
190 x 180 x 80 mm |
| Unit weight |
1.9 kg |
| Busbar material |
Tinned copper |
| Busbar dimensions (h x w) |
8 x 30 mm |
ENVIRONMENTAL |
| Operating temperature range |
-40°C to +60° |
| Storage temperature range |
-40°C to +60° |
| Humidity |
Max. 95% (non-condensing) |
| Protection class |
IP22 |