Our 6 store locations may sell for less if you are able to pick up your battery.
For Dealer and volume purchase enquirers CLICK HERE.
All requests for quotation will be processed within 24hrs eastern standard time, please indicate part, quantity required and your shipping destination commercial quotations.
* Includes shipping to any Canadian provinces except Quebec and the Territories, please contact online for shipping information to those locations.
The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world.
Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations.
The range spans 12V and 24V models from 16A through to 100A.
Models:
12 / 24 Volt
- Quality without compromise
Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.
- Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation)
All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz.
The chargers also accept a 90-400 V DC supply.
- Three outputs that each can supply the full output current
Three isolated outputs to simultaneously charge 3 battery banks
Each output is capable to supply the full rated current.
- Three-stage charging, with temperature compensation
The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/°C (– 1 mV/°F) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries.
Untitled Document
Centaur Charger
|
12/20
|
12/30 24/16
|
12/40
|
12/50
|
12/60 24/30
|
12/80 24/40
|
12/100 24/60
|
Input voltage (V AC)
|
90 - 265
|
Input voltage (V DC)
|
90 - 400
|
Input frequency (Hz)
|
45 - 65
|
Power factor
|
1
|
Charge voltage ‘absorption’ (V DC)
|
14,3 / 28,5 (1)
|
Charge voltage ‘float’ (V DC)
|
13,5 / 27,0 (1)
|
Output banks
|
3
|
Charge current (A) (2)
|
20
|
30 / 16
|
40
|
50
|
60 / 30
|
80 / 40
|
100 / 60
|
Total output ammeter
|
Yes
|
Charge characteristic
|
IUoU (Three stage charging)
|
Recommended battery capacity (Ah)
|
80 - 200
|
120 - 300 45 - 150
|
160 - 400
|
200 - 500
|
240 - 600 120 - 300
|
320 - 800 160 - 400
|
400 - 1000 240 - 600
|
Temperature sensor
|
Internal, - 2mV / °C (- 1mV / °F) per cell
|
Forced cooling
|
Yes, temperature and current controlled fan
|
Protection
|
Output short circuit, over temperature
|
Operating temp. range
|
- 20 to 60°C (0 - 140°F)
|
Ignition protected
|
Yes
|
Humidity (non condensing)
|
max 95%
|
ENCLOSURE
|
Material & Colour
|
aluminium (blue RAL 5012)
|
Battery-connection
|
M6 studs
|
M6 studs
|
M8 studs
|
M8 studs
|
M8 studs
|
M8 studs
|
M8 studs
|
AC-connection
|
screw-clamp 4 mm
2 (AWG 6)
|
Protection category
|
IP 20
|
Weight kg (lbs)
|
3,8 (8.4)
|
3,8 (8.4)
|
5 (11)
|
5 (11)
|
5 (11)
|
12 (26)
|
12 (26)
|
Dimensions hxwxd in mm (hxwxd in inches)
|
355x215x110 (14.0x8.5x4.3)
|
355x215x110 (14.0x8.5x4.3)
|
426x239x135 (16.8x9.4x5.3)
|
426x239x135 (16.8x9.4x5.3)
|
426x239x135 (16.8x9.4x5.3)
|
505x255x130 (19.9x10.0x5.2)
|
505x255x130 (19.9x10.0x5.2)
|
STANDARDS
|
Safety
|
EN 60335-1, EN 60335-2-29, UL 1236
|
Emission Immunity
|
EN 55014-1, EN 61000-3-2
|
Automotive Directive
|
EN 55014-2, EN 61000-3-3
|
1) Standard setting. Optimum charge/float voltages for Flooded Lead-acid, Gel-Cell or AGM batteries selectable by DIP switch.
2) Up to 40°C (100°F) ambient. Output will reduce to approximately 80% of nominal at 50°C (120°F) and 60% of nominal at 60°C (140°F)
|
|
|
 |
 |
 |
 |

|