Our 6 store locations may sell for less if you are able to pick up your battery.
For Dealer and volume purchase enquirers CLICK HERE.
All requests for quotation will be processed within 24hrs eastern standard time, please indicate part, quantity required and your shipping destination commercial quotations.
* Includes shipping to any Canadian provinces except Quebec and the Territories, please contact online for shipping information to those locations.
Adaptive 4-stage charge characteristic: bulk - absorption - float - storage. Two full rated outputs and one 4 Amp output. Universal input 90-265V, 50/60Hz. The Phoenix charger features a microprocessor controlled adaptive battery management system that can be pre-set to suit different types of batteries. The adaptive feature will automatically optimise the charge process relative to the way the battery is being used.
- Adaptive 4-stage charge characteristic: bulk - absorption - float - storage
The Phoenix Charger features a microprocessor controlled 'adaptive' battery management system that can be
preset to suit different types of batteries. The 'adaptive' feature will automatically optimise the process relative
to the way the battery is being used.
- The right amount of charge: variable absorption time
When only shallow discharges occur (a yacht connected to shore power for example) the absorption time is kept
short in order to prevent overcharging of the battery. After a deep discharge the absorption time is
automatically increased to make sure that the battery is completely recharged.
- Preventing damage due to excessive gassing: the BatterySafe mode
If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has
been chosen, the Phoenix Charger will prevent damage due to excessive gassing by automatically limiting the
rate of voltage increase once the gassing voltage has been reached
- Less maintenance and aging when the battery is not in use: the Storage mode
The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the
storage mode float voltage is reduced to 2,2 V/cell (13,2 V for 12 V battery) to minimize gassing and corrosion of
the positive plates. Once a week the voltage is raised back to the absorption level to 'equalize' the battery. This
feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.
- To increase battery life: temperature compensation
Every Phoenix Charger comes with a battery temperature sensor. When connected, charge voltage will
automatically decrease with increasing battery temperature. This feature is especially recommended for sealed
batteries and/or when important fluctuations of battery temperature are expected.
- Battery voltage sense
In order to compensate for voltage loss due to cable resistance, Phoenix Chargers are provided with a voltage
sense facility so that the battery always receives the correct charge voltage.
- Universal 90-265 V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation)
The chargers will accept a 90-400 V DC supply.
- Computer interface
Every Phoenix Charger is ready to communicate with a computer through its RS-485 data port. Together with
our VEConfigure software, which can be downloaded free of charge from our website www.victronenergy.com
and the data link MK3-USB (see accessories), all parameters of the chargers can be customised.
Phoenix Charger
|
12/30
|
12/50
|
24/16
|
24/25
|
Input voltage range (V AC)
|
90-265
|
Input voltage range (V DC)
|
90-400
|
Frequency (Hz)
|
45-65
|
Power factor
|
1
|
Charge voltage 'absorption' (V DC)
|
14,4
|
14,4
|
28,8
|
28,8
|
Charge voltage 'float' (V DC)
|
13,8
|
13,8
|
27,6
|
27,6
|
Storage mode (V DC)
|
13,2
|
13,2
|
26,4
|
26,4
|
Charge current house batt. (A) (2)
|
30
|
50
|
16
|
25
|
Charge current starter batt. (A)
|
4
|
4
|
4
|
4
|
Charge characteristic
|
4 stage adaptive
|
Battery capacity (Ah)
|
100-400
|
200-800
|
100-200
|
100-400
|
Temperature sensor
|
✓
|
✓
|
✓
|
✓
|
Can be used as power supply
|
✓
|
✓
|
✓
|
✓
|
Forced cooling
|
✓
|
✓
|
✓
|
✓
|
Protection (1)
|
a,b,c,d
|
Operating temp. range
|
-20 to 60°C (0 - 140°F)
|
Humidity (non-condensing)
|
max 95%
|
ENCLOSURE
|
Material & Colour
|
aluminium (blue RAL 5012)
|
Battery-connection
|
M6 studs
|
AC-connection
|
screw-clamp 4 mm2 (AWG 11)
|
Protection category
|
IP 21
|
Weight kg (lbs)
|
3,8 (8)
|
Dimensions (hxwxd in mm and inches)
|
350x200x108 mm (13.8x7.9x4.3 inch)
|
STANDARDS
|
Safety
|
EN 60335-1, EN 60335-2-29
|
Emission Immunity
|
EN 55014-1, EN 61000-3-2,
|
Automotive Directive
|
EN 55014-2, EN 61000-3-3
|
Vibration
|
IEC68-2-6:10-150Hz/1.0G
|
1) Protection key:
a) Output short circuit
b) Battery reverse polarity detection
c) Battery voltage too high
d) Temperature too high
2) Up to 40°C (100°F) ambient
|
|
|
|
|
|
|
|